Configure a LabJack device

Connect a LabJack T4 or T7 to the Driver and configure it for tasks.

The Driver connects to LabJack T4, T7, and T8 devices over USB, Ethernet, or Wi-Fi. It finds them with the LabJack LJM library. Before a task can use a device, you configure it.

Prerequisites

Supported
WindowsmacOS
Not supported
LinuxNI Linux RTDocker
  • Install the LJM library on the computer that runs the Driver. The Driver loads it on its next scan, so you do not need to restart the Driver.
  • Connect the device to that computer by USB, or to the same network.

How the Driver finds devices

The Driver looks for LabJack devices every few seconds. A USB device shows in the devices toolbar within a few seconds. A device on the network can take about a minute.

  • Name -> the model and the last four digits of the serial number, such as LJM_dtT7-8422.
  • Location -> the connection, such as LJM_ctUSB or LJM_ctETHERNET.

The Console also shows the notification “New LJM_dtT7 connected”, with a Configure button.

If the Driver does not find a device on the network, for example because the device is on another subnet, add the IP address of the device to the LJM ljm_specific_ips.config file.

Configure a device

Enterprise
  1. In the devices toolbar, right-click the device and select Configure. You can also click Configure in the “New … connected” notification. To list each device that the Driver found, click and select LabJack hardware.
  2. Enter a Name and an Identifier, or click one of the identifiers that the Console suggests.
  3. Click Save. To also open a read task for the device, click Save and create read task.

Do not create LabJack devices in code. The Driver opens a device by its serial number, so only a device that the Driver found works in a task.

Troubleshooting

  • The device does not show in the devices toolbar.
    Cause

    The Driver cannot load the LJM library, or it runs on Linux.

    Fix
    • LJM is not installed -> install the LJM library. The device shows after the next scan.
    • The Driver runs on Linux -> LabJack devices do not work on Linux. Run the Driver on Windows or macOS.

    For more causes, see Troubleshoot hardware.

  • The Driver cannot reach the device.
    Cause

    The task shows “Failed to start task”, “Failed to read data”, or “Failed to write commands”, with this text in the description. Causes:

    • The USB cable or the network connection is lost, or the device has no power.
    • Another program holds the device. A USB device works with one program at a time.
    Fix
    1. Check the USB cable, the network, and the power to the device.
    2. Close Kipling and other LabJack software.

    A running task continues when the Driver reaches the device, and the Driver sets up the channels of the device again. A task that failed to start does not retry. Start it again.

For other problems, see Troubleshoot hardware.